Biological indicators are required for the proof of the sterilization process and release of sterile products

ethylene-oxide-biological-indicators
Image 3

Ethylene Oxide for Instruments

Ethylene oxide is an suitable for a wide range of endoscopes and instruments.

Ethylene oxide for instruments
Image 4

Ethylene Oxide for Instruments

Ethylene oxide is an suitable for a wide range of endoscopes and instruments.

Ethylene oxide for instruments
// end
";} ?>

Ethylene Oxide Gas Suppliers

Our EtO gas is sold in kits, so that you have all the equipment you need without having to order multiple products.

EtO Gas Kits

ARQ-5

ARQ-11

AR-11

ARQ-20

25 x Liner Bags 18" x 24"25 x Liner Bags 22" x 24"25 x Liner Bags 22" x 24"20 x Liner Bags 22" x 36"
25 x 5cc Ampoules25 x 11cc Ampoules25 x 11cc Cartridges20 x 20cc Ampoules
25 x Humidity Chips 18" x 24"25 x Humidity Chips 18" x 24"25 x Humidity Chips 18" x 24"20 x Humidity Chips 18" x 24"
25 x Nylon Tie wraps25 x Nylon Tie wraps25 x Nylon Tie wraps20 x Nylon Tie wraps

Aluminium Cartridges

Available in 100cc, 134cc and 170cc sizes. Aluminium cartridges are for use with our larger industrial sterilizers.

Indicators

Indicator Spots

The stickers can be placed on the outside of items to be sterilized and provide an instant visual confirmation that the items have been exposed to Ethylene Oxide. However, stickers not be used for proof of sterilization.

Chemical Indicators

Similar to the indicator spots, these indicators will change colour however only when exposed to EtO at 54°C

Dosimeters for Ethylene Oxide

The dosimeter, when placed in the liner bag during a cycle, will indicate whether the correct conditions have been met for sterilization; The correct temperature, humidity and gas concentration are required for the dosimeter to initiate a colour change.

Biological Indicators

Bacillus atrophaeus and Geobacillus sterothermophilus

Axis biological indicators suitable for Etylene oxide / ETO(Bacillus atrophaeus) and Steam (Geobacillus stearothermophilus). These indicators are self-contained; the spores are loaded onto a strip within a vial, separated from the growth medium by a second glass vial. The organisms are loaded at a concentration greater than 1x10⁶ and meet the Sterility Assurance Level (SAL) for Ethylene Oxide and steam; thus proving sterilization.

AXIS Incubator

The incubator is designed for use with Axis biological indicators and can be set for 37°C or 59°C dependant on which organism is used.